Step 4:Grounding
Tracer AN series is a common-negative controller, if any of one negative is grounded, all the negative
terminals of PV, Battery will be grounded simultaneously. However, according to the practical
application, all the negative terminals of PV array, battery and load can also be ungrounded, but the
grounding terminal on its shell must be grounded, which may effectively shield the electromagnetic
interference from the outside, and prevent some electric shock to human body due to the
electrification of the shell.
CAUTION: For common-negative system, such as motorhome, it is recommended to use a
common-negative controller; but if in the common-negative system, some common-positive
equipment are used, and the positive electrode is grounded, the controller may be damaged.
Step 5:Connect accessories
 Connect the remote temperature sensor cable (Model:RTS300R47K3.81A)
Connect the remote temperature sensor cable to the interface ❽and place
the other end close to the battery.
CAUTION: If the remote temperature sensor is not connected to the controller,, the default
setting for battery charging or discharging temperature is 25 °C without temperature compensation.
 Connect Remote Battery Voltage Sensor (Model:RVBS300B3.81)
Connect the remote battery voltage sensor cable to the interface ⓫and connect the other end to the
battery terminals.
 Connect the accessories for RS485 communication, refer to the accessories list.
Step 6:Powered on the controller
Turn on the battery fuse to power on the controller, then check the LCD is OFF or the fault indictor is
ON when the controller is normal.
CAUTION: If the controller is not operating properly or the battery indicator on the controller
shows an abnormality, please refer to 4.2 "Troubleshooting".