Making A Setting For Linking Two M/E Banks - Sony MVS-8000SF User Manual

Hide thumbs Also See for MVS-8000SF:
Table of Contents

Advertisement

• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
Knob Parameter
4
7
In the <Bus> group, select any of the following.
Enable: Enable the GPI link setting for the selected bus.
Disable: Disable the GPI link setting for the selected bus.
All Enable: Enable the GPI link setting for all buses.
Setting the delay value
1
In the Switcher >Link >GPI Link Adjust menu, turn the knobs to select the
output port for which you want to set the delay value, and the
corresponding delay value.
Knob Parameter
1
5
2
Press [Delay Set].
This confirms the delay value, which is reflected in the status area.

Making a Setting for Linking Two M/E Banks

You can link any two M/E banks for some operations by using the Switcher
>Link >M/E Link menu.
The operations for which you can link two M/E banks are as follows.
• Transition execution (auto transition, cut, and fader lever operation)
• Next transition selection
• Transition type selection
Notes
Clip transition execution is excluded from the above transition execution
operations.
1
In the Switcher >Link menu, press [M/E Link].
Adjustment
Bus
Bus selection
Adjustment
GPI Port
GPI output port for the
setting
Delay
Delay value for the output
port
Setting values
1 to 114
Setting values
1 to 8
0 to 300 (fields)
Settings Relating to Function Links (Link Menu)
1095

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mvs-8000

Table of Contents