5   OPERATION
4) Lock the new inlet wire guide into place using the wire guide quick lock (A).

5.11.2 Middle wire guide

1) Apply a small amount of pressure to the middle wire guide clip and remove the middle wire
guide (A).
2) Push in the correct type of wire guide (according to the WEAR PARTS appendix). The clip
automatically locks the wire guide when in the correct position.

5.11.3 Outlet wire guide

1) Remove the lower right feed roller (see the "Changing feed rollers" section).
2) Remove the middle wire guide (see the "Middle wire guide" section).
3) Unlock the outlet wire guide quick lock (A) by folding it out.
4) Remove the outlet wire guide (B).
5) Install the correct outlet wire guide (according to the WEAR PARTS appendix).
6) Lock the new outlet wire guide into place using the wire guide quick lock (A).
7) Reattach the second pair of feed rollers and reapply the roller pressure (see the "Changing feed
rollers" section).