5 OPERATION
4.
Remove the feed rollers and install the correct ones (according to the WEAR PARTS
appendix).
5.
Reapply pressure to the feed rollers by pushing the swing arms (C) downward and
secure them using the tensioner units (B).
6.
Lock the rollers into place by rotating the roller quick locks (A).
7.
Close and lock the left door of the wire feeder.
5.11

Changing the wire guides

When changing to a different type of wire, the wire guides may need to be changed to match
the new type of wire. For information about the correct wire guides depending on wire
diameter and type, see the WEAR PARTS appendix. For tips about easy access to essential
wear parts, see the "Wear parts storage compartment" section in this manual.
5.11.1

Inlet wire guide

1.
Unlock the inlet wire guide quick
lock (A) by folding it out.
2.
Remove the inlet wire guide (B).
3.
Fit the correct inlet wire guide
(according to the WEAR PARTS
appendix).
4.
Lock the new inlet wire guide into
place using the wire guide quick
lock (A).
5.11.2

Middle wire guide

1.
Apply a small amount of pressure to
the middle wire guide clip and
remove the middle wire guide (A).
2.
Push in the correct type of wire
guide (according to the WEAR
PARTS appendix). The clip
automatically locks the wire guide
when in the correct position.