6   CONTROL PANEL
6.1.2

Push encoder knobs

Push encoder knob for setting voltage, dynamics and arc length (4)
This knob increases or decreases the value of voltage, arc length and dynamics depending on the
selected application.
For GMAW, press the knob to switch between voltage and dynamics.
Indicator
Description
Arc dynamics
Supplementary function for correction of dynamic arc behavior. The influence of
dynamics depends on the selected welding method and application mode used.
The indicator is lit when the dynamics value is displayed in the display (2).
This function is inactive by default in the external control panel but can be activated
in the internal control panel. For more information, see section "Front panel
functionality"
Arc length
This parameter provides the possibility of arc length adjustment from a shorter arc
using a negative offset to a longer arc using a positive offset setting.
Measured voltage
Measured value in the display for welding voltage V is an average numerical value
which is calculated during the welding excluding the weld termination.
Push encoder knob for setting wire feed speed / A / ~A (9)
This knob increases or decreases the value of wire feed speed, amperage and estimated amperage
depending on the selected application.
Indicator
Description
Wire feed speed
To set a unit of wire feed speed, use "System settings" in the internal control panel.
This indicator is lit based on the selection and displays the value (11).
Measured amperage
Measured value in the display for welding current A is an average numerical value
which is calculated during the weld excluding the weld termination.
Estimated amperage
Estimated value of current to be delivered during welding. Condition of the distance
from contact tip to work piece will affect the correspondence between the estimated
value and the actual measured amperage value during welding.
This function is inactive by default in the external control panel but can be activated
in the internal control panel. For more information, see section "Front panel
functionality."
6.1.3

Buttons

2T / 4T button (5)
This button is used for changing between 2-stroke and 4-stroke mode in GMAW applications.
0463 786 001