9   EVENT CODES

Communication fault

x14
This event code is displayed due to one of the following:
114 - Weld control communication error.
114 - Internal communication warning.
114 - Connection to main control lost.
114 - Fieldbus interface lost.
1.
Check that all the equipment is correctly connected.
2.
Acknowledge by pressing any buttons on the control panel.
3.
Do not turn OFF the system and contact service technician.

Short circuit detected

x15
This event code is displayed due to one of the following:
215 - Weld contact detected at startup.
1.
Make sure that the welding cables are properly installed on the weld terminals.
2.
Acknowledge by pressing any buttons on the control panel.
3.
Contact service technician.

High open circuit voltage fault

x16
This event code is displayed due to one of the following:
216 - Voltage sensor lost.
216 - OCV level is too high.
216 - Current brake module lost.
216 - Current brake function error.
1.
In case of voltage sensor lost, contact service technician. Otherwise restart the system.

Lost contact with another unit

x17
This event code is displayed due to one of the following:
017 - Mandatory node missing.
017 - Critical node lost.
1.
Check the cable connections between the subsystem (wire feeder and power source).
2.
Acknowledge by pressing any buttons on the control panel.
3.
Contact service technician.

Internal memory fault

x18
This event code is displayed due to one of the following:
018 - Partition data storage warning.
1.
Make sure that network connection is stable with WeldCloud and acknowledge.
0463 786 001
- 58 -
© ESAB AB 2023

Advertisement

Table of Contents
loading