6   CONTROL PANEL
2) Set the weld parameters based on the weld application selected.
3) Press the desired job numbers (1, 2 or 3) in the panel for 2 seconds.
NOTE!
While saving a job, if the existing job number with pre-saved data is selected. It will
overwrite the new weld parameters.
6.5

Tools

6.5.1

Error logs

Error logs
There are two types of error levels. A warning symbol appears in yellow, which prevents a new weld.
The error symbol is represented in red, resulting in the stoppage of a current weld.
The error log will have history errors and active errors. Pressing the push button for the corresponding
error will show the incident description and time.