Middle Wire Guide; Outlet Wire Guide; Roller Pressure - ESAB RobustFeed PRO Instruction Manual

Table of Contents

Advertisement

5 OPERATION
5.12.2

Middle wire guide

1.
Apply a little pressure on the middle
wire guide clip and pull out the
middle wire guide (A).
2.
Push in the correct type of wire
guide (according to the WEAR
PARTS appendix). The clip
automatically locks the wire guide
when in the correct position.
5.12.3

Outlet wire guide

1.
Remove the lower right feed roller
(see the "Changing feed rollers"
section).
2.
Remove the middle wire guide (see
the "Middle wire guide" section).
3.
Unlock the outlet wire guide quick
lock (A) by folding it out.
4.
Remove the outlet wire guide (B).
5.
Install the correct outlet wire guide
(according to the WEAR PARTS
appendix).
6.
Lock the new outlet wire guide using
the wire guide quick lock (A).
7.
Reattach the second pair of feed
rollers and reapply the roller
pressure (see the "Changing feed
rollers" section).
5.13

Roller pressure

The roller pressure should be adjusted separately on each tensioner unit, depending on used
wire material and diameter.
Start by making sure that the wire moves smoothly through the wire guide. Then set the
pressure of the wire feeder's pressure rollers. It is important that the pressure is not too high.
0463 658 101
- 22 -
© ESAB AB 2023

Advertisement

Table of Contents
loading