8   EVENT CODES

Communication error

95
The system's CAN bus has temporarily ceased to work due to excessive load.
The current welding process is stopped.
1.
Check the equipment to ensure that only one wire feed unit or remote control unit is connected.
2.
If the error is repeated, send for a service technician.

Current servo saturation

100
The welding process has stopped because it has not advanced within 10 seconds.
1.
Is reset at next weld start. If the error persists, send for a service technician.

A motor has stopped

168
There are no pulses from the motor pulse transducer.
For LAF and TAF: 168 = Motor M1 (Wire feeder motor), 169 = Motor M2 (Travel motor).
1.
Check the motor cables. Replace the pulse transducer.
A motor has stopped
169
There are no pulses from the motor pulse transducer.
For LAF and TAF: 168 = Motor M1 (Wire feeder motor), 169 = Motor M2 (Travel motor).
1.
Check the motor cables. Replace the pulse transducer.
2310 Current servo saturation
The power source has temporarily delivered maximum current.
1.
If the error persists, try lowering the weld data.

3205 High DC voltage

1.
Check if the main voltage is too low or too high.

4201 High temperature

The power source has overheated. Welding is cancelled. Welding is permitted again when the
temperature falls below the maximum temperature parameter.
1.
Check that the cooling air inlets or outlets are not obstructed or clogged with dirt.
2.
Check the duty cycle being used, to make sure that the equipment is not being overloaded.
4202 High temperature
The power source has overheated. Welding is cancelled. Welding is permitted again when the
temperature falls below the maximum temperature parameter.
1.
Check that the cooling air inlets or outlets are not obstructed or clogged with dirt.
2.
Check the duty cycle being used, to make sure that the equipment is not being overloaded.
0463 893 001