  • Page 1 SDF-250 Instruction manual 0448 020 001   GB   20230315...
  • Page 3: Table Of Contents

    Meaning of symbols ...................... Safety precautions ......................... INTRODUCTION ....................Oven use and purpose ........................TECHNICAL DATA ........................... INSTALLATION ........................Operation ......................... ORDERING NUMBERS ..........................WIRING DIAGRAM ........................ORDERING SPARE PARTS 0448 020 001 - 3 - © ESAB AB 2023...
  • Page 4: Safety

    INTRODUCTION Oven use and purpose The SDF-250 range of drying and storing ovens are large temperature-controlled cabinets for welding powder flux in a typical industrial set up. They are designed for convenient top loading and bottom removal of welding flux. The easy-to-use digital controller sets and regulates the temperature over a wide range for baking, drying, and storing.
  • Page 5: Technical Data

    Once the power is turned on, depending upon the type of your oven i.e 1Φ one green lamp will glow or 3Φ three green pilot lamps will glow. If the lamps or not glowing, then check the power connection. Refer the below image. 0448 020 001 - 5 - © ESAB AB 2023...
  • Page 6: Ordering Numbers

    ORDERING NUMBERS Ordering number Denomination Type Notes 0700 100 000 Stationary submerged arc welding powder SDF- Three phase drying oven 380- 415 V AC 50/60 Hz Technical documentation is available on the Internet at: www.esab.com 0448 020 001 - 6 - © ESAB AB 2023...
  • Page 7: Wiring Diagram

    APPENDIX WIRING DIAGRAM 0448 020 001 - 7 - © ESAB AB 2023...
  • Page 8: Ordering Spare Parts

    0700 100 023 Contactor 110C UNI 110 V 0700 100 018 Power switch 0700 100 019 Terminal 0700 100 020 Air valve 0700 100 164 Fiberglass wick SDF-250 0700 100 165 Thermocouples 0448 020 001 - 8 - © ESAB AB 2023...
  • Page 9 APPENDIX 0448 020 001 - 9 - © ESAB AB 2023...
  • Page 10 For contact information visit http://esab.com ESAB AB, Lindholmsallén 9, Box 8004, 402 77 Gothenburg, Sweden, Phone +46 (0) 31 50 90 00 manuals.esab.com...