8 EVENT CODES
Communication error
14
The system's CAN bus has temporarily ceased to work due to excessive load.
The current welding process is stopped.
1.
Check the equipment to ensure that only one wire feed unit or remote control unit is connected.
2.
If the error is repeated, send for a service technician.
Lost contact with the unit
17
Lost contact with a unit.
1.
Check wiring and the connector between the control unit and power source.
No gas flow
32
Start prevented.
1.
Check the gas valve, hoses and connectors.
High welding current
43
Power source have switched off the welding process because the current has exceeded the maximum
current parameter for the power source.
1.
Is reset at next weld start. If the error persists, send for a service technician.
Current servo saturation
44
The welding process has stopped because it has not advanced within 10 seconds.
1.
Is reset at next weld start. If the error persists, send for a service technician.
High welding current
71
Power source have switched off the welding process because the current has exceeded the maximum
current parameter for the power source.
1.
Is reset at next weld start. If the error persists, send for a service technician.
High inductance
88
Inductance is too high, depending on long welding cables and/or high weld data.
1.
Adjust the welding data.
Internal communication error (warning)
93
The load on the system's CAN-bus is temporarily too high. The power source may have lost contact
with the control unit
1.
Check that all the equipment is correctly connected. If the error persists, send for a service
technician.