SETUP AND CALIBRATION, CONT.
A cLr= (Auto Clear ID)
The a clr= (Auto Clear ID) prompt determines whether the ID is automatically cleared
after printing the ticket. Note that it is only displayed when id= YES is selected.
With the display showing a clr=, press the ENTER key to show the current value. If the
setting displayed is acceptable, press the ENTER key again to save it. Otherwise, using the
numeric keys, 0/NO or 1/YES, enter the new setting, then press the ENTER key to save it.
A clr=1 (Yes)
Automatically clears the ID after the
ticket has printed.
oPEr = 1 (ID Storage)
ALAr? (Weight Alarm)
m
The Weight Alarm will energize PWC1 for a selected time when the weight exceeds a
threshold weight.
If the setting displayed is acceptable, press the ENTER key to save it. Otherwise, using the
numeric keys, 0/NO or 1/YES, enter the new setting, then press the ENTER key to save it.
h oUt= (High State Before Cutoff)
If the comparator outputs are to be High before cutoff, answer YES to this prompt.
oPEr = 2 (Digital Fill Control)
SPEEd=X (Single or Two Speed Filling)
X=1
Single speed filling
X=2
Two speed filling
G SEQ=X (Gate Sequence for Two Speed Filling)
X=1
AB->B
When filling begins both the "A" (fast) and "B" (slow) outputs will be on until the weight
reaches the FAST weight value. The "A" output is turned off and the "B" output remains
on until the SLOW weight value is reached.
X=2
A->B
When filling begins the "A" (fast) output will be on until the weight reaches the FAST
weight value. The "A" output is turned off and the "B" output is turned on. The "B" output
remains on until the SLOW weight value is reached.
X=3
CHATTER-GATE
When filling begins the "A" (fast) output will be turned on, when the FAST weight value is
reached the "A" output will pulse on/off until the SLOW weight is reached.
Atri= (Auto Trim Weight Compensation)
m
YES After the target weight minus the trim weight is reached and the scale stabilizes,
the trim weight will be automatically adjusted. The adjustment is based on the
difference between the target weight and the actual weight filled.
NO
No trim weight adjustment will be made at the completion of a filling operation.
APrnt= (Automatic Print)
YES The time, date, and weight will be automatically printed at the conclusion of the fill.
NO
No automatic print at the conclusion of the fill.
8200-0727-2M Rev A  210FE Installation & Technical
46
a clr=0 (No)
ID is not cleared when ticket prints