Cardinal 210FE Installation And Technical Manual page 98

Weight indicator
Hide thumbs Also See for 210FE:
Table of Contents

Advertisement

DIGITAL FILL CONTROL MODE OPERATION, CONT.
To Start a Fill Operation
1. Press the Fn key. If the gross weight is within the zero tolerance weight (dGAtE=YES), the
indicator will tare off the gross weight and display zero net weight (if AtArE=YES) and the
display will show StArt?.
NOTE: If the Gross weight is not within the zero tolerance weight, C2ERO will be displayed
momentarily.
2. Press the ENTER key to start the fill operation, or press the NO key and then the ENTER
key to abort the operation.
3. The PWC1 annunciator will turn on and the PWC1 output control will turn on.
If the G SEQ=1 (AB->B) then the PWC2 annunciator will turn on and the PWC2 output
control will turn on.
4. When the displayed weight reaches the FASt=XXXXXX value (minus the Trin=XXXXXX
value), the PWC1 output control is switched off and the PWC1 annunciator is turned off.
5. If G SEQ=2 (A->B) then the PWC2 annunciator and output control will be turned on.
6. If G SEQ=3 (Chatter-gate), then the PWC1 annunciator and output control will be turned
on for the Ct on time.
7. If G SEQ=2 (A->B), then PWC2 annunciator and output control will stay on until the weight
SLo-Trin
reaches the
w
8. If G SEQ=3 (Chatter-gate), then the PWC1 annunciator and output will pulse on and off
until the weight reaches the
9. If the fill control parameters were retrieved from memory, then the filled weight will be
added to the accumulator and the count will be incremented, and saved to the ID.
10. When all motion stops, the weight will be printed (if a printer is attached and APrnt=YES).
The following is an example of the information printed.
14:54 12/13/2014
#53
12000 lb G
00 lb T
12000 lb N
11. If Atrin=YES was selected in setup, the trim weight will be recalculated and stored in
memory and the displayed weight value added to the PRESET and GROSS or NET
accumulators.
12. If dGAtE=YES and AdiSC=YES were selected in setup, then the completed fill operation
will immediately begin to discharge and PWC3 annunciator and output control are turned
on. The weight display will change from net to gross. The discharge will continue until the
scale weight returns to zero within the 0 TOL=XX value.
13. If dGAte=YES and AdiSC=NO were selected in setup, then the completed fill operation
will wait for the Fn key or the optional START pushbutton to be pressed for the discharge
to begin (PWC3 annunciator and output control are turned on). The weight display will
change from net to gross. The discharge will continue until the scale weight returns to zero
within the 0 TOL=XX value
8200-0727-2M Rev A  210FE Installation & Technical
92
m
weight.
SLo-Trin
weight.
m
w

Advertisement