Cardinal 210FE Installation And Technical Manual page 97

Weight indicator
Hide thumbs Also See for 210FE:
Table of Contents

Advertisement

DIGITAL FILL CONTROL MODE OPERATION, CONT.
TWO SPEED OPERATION
USING STORED ID DFC SETTINGS:
To recall the stored settings from memory (setup parameter StOr?=YES), press the PRESET
key. The display will show StOr=, press the ENTER key, the current ID (if any) will be
displayed. If the displayed ID is correct, press the ENTER key, otherwise, enter the desired ID
and press ENTER. If a new ID was entered, the Fill weight and Trim weight will be retrieved
from memory.
The display will change to show FASt =, press the ENTER key and the current fast weight
will be displayed. If this value is acceptable press the ENTER key, otherwise, use the numeric
keys to enter a new fast weight and press the ENTER key.
The display will change to show
SLo =, press the ENTER key and the current slow weight will
w
be displayed. If this value is acceptable press the ENTER key, otherwise, use the numeric
keys to enter a new slow weight and press the ENTER key.
NOTE: The slow weight is the target weight and MUST be greater than the fast weight.
The display will change to show trin =, press the ENTER key and the current trim weight
will be displayed. If this value is acceptable press the ENTER key, otherwise, use the numeric
keys to enter a new trim weight and press the ENTER key.
NOTE: If the Fast, SLow, or trim values are changed, they will NOT be saved to the ID in
memory.
If the dGAtE=YES, then the display will change to 0toL=. Press the ENTER key and the
current zero tolerance weight will be displayed. If this value is acceptable press the ENTER
key, otherwise, use the numeric keys to enter a new zero tolerance weight and press the
ENTER key.
If the Chatter-Gate operation (G SEq=3) was selected in setup, then the Ct on= prompt will
be displayed. Press the ENTER key and the current time on setting will be displayed. If the
time is acceptable the press the ENTER key, otherwise, use the numeric keys to enter a new
time and press the ENTER key. The valid range is 0.00 to 99.9 seconds.
The current Gross/Net weight will be displayed.
8200-0727-2M Rev A  210FE Installation & Technical
91

Advertisement

Table of Contents
loading