Digital Scale Diagnostics; On Screen Diagnostics - Cardinal SMARTCELL 225D Installation And Technical Manual

Hide thumbs Also See for SMARTCELL 225D:
Table of Contents

Advertisement

There are four main components to 225D Digital Scale Diagnostics:
• On Screen Diagnostics – Critical errors that alert operator from the main screen of setup
issues or hardware problems.
• Diagnostic Menu – A set of diagnostic tools that give a technician more information
about each load cell.
• Hardware Diagnostics – LEDs on the DLC controller alert technicians of
communications status.
• iSite – Web-based repository for historical load cell data that will be tracked for slow
degradation of load cell integrity (for example a single load cell that is drifting away
from zero). iSite will also receive all the hardware errors found by the 225D SmartCell
Weight Indicator.

On Screen Diagnostics

The following messages will be shown to the operator on the main weight screen in real-time
when an error happens.
COMMUNICATION ERROR BETWEEN INDICATOR AND SCALE
-------
NO WEIGHT
COMMUNICATION ERROR BETWEEN
INDICATOR AND SCALE
Probable Cause
The homerun cable is
damaged or disconnected.

DIGITAL SCALE DIAGNOSTICS

ID
COUNT
• Check that cable is connected correctly.
• Check cable for damage.
• Use caution on the amount of insulation stripped for
the connector. Center wires could short. Must be
shorter than the center connector.
• Check connector for random strands of wire.
• Verify that connector is clear of debris.
8200-0753-0M Rev D • 225D Weight Digital Indicator
lb
G
Items to Check
17

Advertisement

Table of Contents
loading

Table of Contents