Usb Interface And Usb Cable Installation - Cardinal 210FE Installation And Technical Manual

Weight indicator
Hide thumbs Also See for 210FE:
Table of Contents

Advertisement

USB Interface
The 210FE indicator USB Interface is a standard full speed (12Mbps) USB 2.0 device port. It
can be connected to a USB 2.0 host, with the Cardinal Scale 8200-B163-0A USB CABLE or an
industry standard USB 2.0 cable, to be used as the COM3 serial I/O port set to 8 bit data, 1
stop bit, no parity, 9600 to 115.2k baud. Refer to the Setup, SIO Serial I/O section of this
manual.
The USB port is enabled with jumpers J4 and J5 (see Figure No. 15) set to the USB position
(utilizing the indicator COM3 serial port) and the USB PWR jumper, J10 (see Figure No. 15),
set to the BUS position to be powered by the USB host or to the VCC position to be powered
by the 210FE indicator main PC board. Follow the "Driver Installation Instructions for
Indicator's USB Port" in conjunction with the usb2ser.inf file located on the 210FE Indicator
Installation and Technical Manual CD.
8200-B163-0A Water Tight USB Cable Installation
1. Remove the 16 acorn nuts securing the back panel to main housing.
2. Remove a gland connector from the back panel. Refer to Figure No. 2 for illustration of
connector layout.
3. Loosen the gland connector nut from the 8200-B163-0A cable/gland assembly (see
Figure No. 9) and slip off over the 5-pin cable connector and ground wire.
4. Insert the 5-pin connector and ground wire through the rear panel.
5. Slip the gland connector nut back over the 5-pin connector and ground wire and tighten on
the gland connector on the rear panel.
6. Pull the USB cable through the gland to reach P4, the USB-B header.
7. Plug the USB cable connector onto the USB-B, P4 header, referring to Figure No. 15 for
the location of P4. Tighten the gland cable nut on the USB cable.
GROUND WIRE
8. To attach the ground wire (see Figure No. 11); remove a 6-32 nut and washer from the
corner of the main board.
9. Connect the ground wire from the USB cable by placing the ring terminal over the 6-32
threaded stud.
10. Reinstall the washer and 6-32 nut and tighten.
Standard USB Cable Installation
1. Remove the 16 acorn nuts securing the back panel to main housing.
2. Remove a gland connector from the back panel. Refer to Figure No. 2 for illustration of
connector layout.
3. Slip the cable through the hole in the rear panel and into the enclosure.
4. Plug the USB cable into the USB-B connector P6. See Figure No. 15 for the location of P6.
8200-0727-2M Rev A  210FE Installation & Technical
INSTALLATION, CONT.
Figure No. 11
REMOVE THIS NUT
13