Digital Scale Diagnostics; On Screen Diagnostics - Cardinal SMARTCELL 825D Installation And Technical Manual

Table of Contents

Advertisement

On Screen Diagnostics

The On Screen Diagnostics messages are critical errors that alert the operator from the main
screen of setup issues or hardware problems. These messages will be shown to the operator
on the main weight screen in real-time when the error happens.
COMMUNICATION ERROR BETWEEN INDICATOR AND SCALE
Probable Cause
The homerun cable is
damaged or disconnected.
46

DIGITAL SCALE DIAGNOSTICS

• Check that cable is connected correctly.
• Check cable for damage.
• Use caution on the amount of insulation stripped for
the connector. Center wires could short. Must be
shorter than the center connector.
• Check connector for random strands of wire.
• Verify that connector is clear of debris.
8545-0980-0M Rev C • 825D Weight Digital Indicator