Troubleshooting Record Sheet
Date of Problem
Year/month/day:
Representative
Customer
User
Details of the Problem
Inverter Model
CIMR-G7A
Serial No.
J
Manufacturing Date Year/month/day:
1. Crane 2. Elevator 3. Escalator 4. Conveyor 5. Textile machine 6. Extruder
Application
7. Fan or blower 8. Processing machine 9. Other :
Customer
1. Tires 2. Steel 3. Textile machine 4. Paper 5. Film 6. Semiconductors 7. Other :
1. AC reactor /DC reactor 2. Input noise filter 3. Braking Resistor 4. Braking Unit (CDBR)/
Peripheral Devices
Braking Resistor Unit (LKEB) 5. Output noise filter 6. Zero-phase reactor 7. Other :
Details of the
1. CPF 2. GF 3. OC 4. OL1/OL2 5. RR 6. Operator not lit. 7. Other :
Problem
Details of Primary
1. Implemented. Details and results:
Action
2. Not implemented.
Inverter Internal Information When the Problem Occurred
Constant
U1-14
Software number
U2-01
Current fault
U2-02
Previous fault
U2-03
Reference frequency at fault
U2-04
Output frequency at fault
U2-05
Output current at fault
U2-06
Motor speed at fault
U2-07
Output voltage reference at fault
U2-08
DC bus voltage at fault
U2-09
Output power at fault
U2-10
Torque reference at fault
U2-11
Input terminal status at fault
U2-12
Output terminal status at fault
U2-13
Operation status at fault
U2-14
Cumulative operation time at fault
U2-21
Peak hold current at fault
U2-22
Peak hold output frequency at fault
U3-01
Most recent fault
U3-02
Second most recent fault
U3-03
Third most recent fault
U3-04
Fourth/oldest fault
U3-05
Cumulative operation time at fault
U3-06
Accumulated time of second fault
U3-07
Accumulated time of third fault
U3-08
Accumulated time of fourth/oldest fault
A1-02
Control method selection
C6-02
Carrier frequency selection
L8-38
Carrier frequency reduction selection
E1-13
Base voltage
E2-01
Motor rated current
E2-07
Motor iron saturation coefficient 1
Name
Troubleshooting Record Sheet
Setting
Remarks
The PRG No. from the nameplate on the
side of the Inverter is acceptable.
Cleared with reset.
Displayed when A1-02 = 1 through 4.
Displayed when A1-02 = 2 through 4.
Applicable when U1-14 is 21039 and later.
Applicable when U1-14 is 21039 and later.
10
45
10-