YASKAWA Varispeed G7 Series Instruction Manual page 80

General purpose inverter (advanced vector control)
Hide thumbs Also See for Varispeed G7 Series:
Table of Contents

Advertisement

Wiring the PG-D2
Wiring examples are provided in the following illustrations for the PG-D2.
Three-phase, 200
VAC (400 VAC)
Wiring the PG-X2
Wiring examples are provided in the following illustrations for the PG-X2.
Three-phase,
200 VAC (400
VAC)
-44
2
Inverter
Shielded twisted-pair wires must be used for signal lines.
Do not use the pulse generator's power supply for anything other than the pulse generator (encoder).
Using it for another purpose can cause malfunctions due to noise.
The length of the pulse generator's wiring must not be more than 100 meters.
Fig 2.28 PG-D2 Wiring
Inverter
R/L1
U/T1
S/L2
V/T2
T/L3
W/T3
Shielded twisted-pair wires must be used for signal lines.
Do not use the pulse generator's power supply for anything other than the pulse generator (encoder).
Using it for another purpose can cause malfunctions due to noise.
The length of the pulse generator's wiring must not be more than 100 meters.
The direction of rotation of the PG can be set in user constant F1-05 (PG Rotation). The factory preset if
for motor forward rotation, A-phase advancement.
Fig 2.29 PG-X2 Wiring
Power supply +12 V
Power supply 0 V
Power supply +5 V
Pulse input + (A/B phase)
Pulse input - (A/B phase)
Pulse monitor output
Power supply +12 V
Power supply 0 V
Power supply +5 V
A-phase pulse input (+)
A-phase pulse input (-)
B-phase pulse input (+)
B-phase pulse input (-)
A-phase pulse monitor output
B-phase pulse monitor output
Z-phase pulse monitor output

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents