Specifications Of Options And Peripheral Devices - YASKAWA Varispeed G7 Series Instruction Manual

General purpose inverter (advanced vector control)
Hide thumbs Also See for Varispeed G7 Series:
Table of Contents

Advertisement

Specifications of Options and Peripheral Devices

The following options and peripheral devices can be used for the Inverter. Select them according to the
application.
The following option boards are available
Type
Speed
(Fre-
quency)
Refer-
ence
Option
Boards
Built-in
(con-
nect to
con-
nector)
Moni-
toring
Option
Boards
-6
9
Table 9.4 Option Boards
Code Num-
Name
ber
Analog Ref-
73600-
erence Board
C001X
AI-14U
Analog Ref-
73600-
erence Board
C002X
AI-14B
Digital Refer-
73600-
ence Board
C003X
DI-08
Digital Refer-
73600-
ence Board
C016X
DI-16H2
Analog Mon-
73600-
itor Board
D001X
AO-08
Analog Mon-
73600-
itor Board
D002X
AO-12
Digital Out-
73600-
put Board
D004X
DO-08
2C-Relay
73600-
Output Board
D007X
DO-02C
.
Function
Enables high-precision, high-resolution setting of analog
speed references.
• Input signal ranges: 0 to 10 V (20 kΩ), 1 channel
4 to 20 mA (250 Ω), 1 channel
• Input resolution:
14-bit (1/16384)
Enables high-precision, high-resolution setting of analog
speed references.
• Input signal ranges: -10 to 10 V (20 kΩ)
4 to 20 mA (500 Ω), 3 channels
• Input resolution:
13-bit + sign (1/8192)
Enables 8-bit digital setting of speed references.
• Input signal:
8-bit binary
2-digit BCD + sign signal + set signal
• Input voltage: +24 V (isolated)
• Input current: 8 mA
Enables 16-bit digital setting of speed references.
• Input signal:
16-bit binary
4-digit BCD + sign signal + set signal
• Input voltage: +24 V (isolated)
• Input current: 8 mA
With 16-bit/12-bit switch.
Converts analog signals to monitor the Inverter's output status
(output frequency, output current, etc.) to absolute values and
outputs them.
• Output resolution: 8 bits (1/256)
• Output voltage: 0 to +10 V (not insulated)
• Output channels: 2 channels
Output analog signals to monitor the Inverter's output status
(output frequency, output current, etc.).
• Output resolution: 11 bits (1/2048) + sign
• Output voltage: -10 to +10 V (not insulated)
• Output channels: 2 channels
Outputs isolated digital signals to monitor the Inverters oper-
ating status (alarm signals, zero-speed detection, etc.)
Output form: Photocoupler output, 6 channels
(48 V, 50 mA max.)
Relay contact outputs, 2 channels
(250 VAC: 1 A max., 30VDC: 1 A max.)
Provides two multi-function outputs (DPDT relay contacts) in
addition to those provided by the Inverter.
Document
Number
TOE-C736-
30.13
TOE-C736-
30.14
TOE-C736-
30.15
TOE-C736-
40.7
TOE-C736-
30.21
TOE-C736-
30.22
TOE-C736-
30.24
TOE-C736-
40.8

Hide quick links: