YASKAWA Varispeed G7 Series Instruction Manual page 342

General purpose inverter (advanced vector control)
Hide thumbs Also See for Varispeed G7 Series:
Table of Contents

Advertisement

Related Constants
Name
Con-
stant
Display
Number
PID control
method selec-
tion
b5-01
PID Mode
Proportional
Sets P-control proportional gain
gain (P)
as a percentage.
b5-02
P-control is not performed when
PID Gain
the setting is 0.00.
Integral (I) time Sets I-control integral time in 1-
second units.
b5-03
I-control is not performed when
PID I Time
the setting is 0.0.
Integral (I) limit Sets the I-control limit as a per-
b5-04
centage of the maximum output
PID I Limit
frequency.
Derivative (D)
Sets D-control derivative time in
time
1-second units.
b5-05
D-control is not performed when
PID D Time
the setting is 0.00.
PID upper limit Sets the upper limit after PID-
b5-06
control as a percentage of the
PID Limit
maximum output frequency.
PID offset
Sets the offset after PID-control
adjustment
b5-07
as a percentage of the maximum
output frequency.
PID Offset
PID first order
Sets the time constant for low
lag time con-
pass filter for PID-control outputs
stant
b5-08
in 1-second units.
PID Delay
Not usually necessary to set.
Time
PID output
Select forward/reverse for PID
characteristics
output.
selection
b5-09
Output Level
Sel
PID output gain
b5-10
Sets output gain.
Output Gain
PID reverse
output selection
b5-11
Output Rev Sel
0 limit when reverse prohibit is
selected using b1-04.
Description
0: Disabled
1: Enabled (Deviation is D-
controlled.)
2: Enabled (Feedback value is D-
controlled.)
3: PID control enabled
(frequency reference + PID
output, D control of deviation)
4: PID control enabled
(frequency reference + PID
output, D control of feedback
value).
0: PID output is forward.
1: PID output is reverse
(highlights the output code)
0: 0 limit when PID output is
negative.
1: Reverses when PID output is
negative.
Control Methods
Change
Setting
Factory
during
V/f
Range
Setting
Opera-
V/f
with
tion
PG
0 to 4
0
No
A
A
0.00
to
1.00
Yes
A
A
25.00
0.0 to
1.0 s
Yes
A
A
360.0
0.0 to
100.0
Yes
A
A
100.0
%
0.00 to
0.00 s
Yes
A
A
10.00
0.0 to
100.0
Yes
A
A
100.0
%
-100.0
to
0.0%
Yes
A
A
+100.0
0.00 to
0.00 s
Yes
A
A
10.00
0 or 1
0
No
A
A
0.0 to
1.0
No
A
A
25.0
0 or 1
0
No
A
A
Individual Functions
MEMO
Open
Open
BUS
Flux
Loop
Loop
Regis-
Vec-
Vector
Vector
ter
tor
1
2
A
A
A
1A5H
A
A
A
1A6H
A
A
A
1A7H
A
A
A
1A8H
A
A
A
1A9H
A
A
A
1AAH
A
A
A
1ABH
A
A
A
1ACH
A
A
A
1ADH
A
A
A
1AEH
A
A
A
1AFH
6-
109