Recommended Peripheral Devices - YASKAWA VS MINI J7 Series Instruction Manual

Compact general-purpose inverter (voltage vector control)
Hide thumbs Also See for VS MINI J7 Series:
Table of Contents

Advertisement

All manuals and user guides at all-guides.com

• Recommended Peripheral Devices

It is recommended that the following periheral devices be mounted between the AC
main circuit power supply and VS mini J7 input terminals R/L1, S/L2, and T/L3.
• MCCB (Molded-case circuit breaker):
A circuit breaker should be connected for wiring protection.
• Magnetic contactor:
Mount a surge suppressor on the coil (refer to the table shown below).
To assure optimum inverter life when using a magnetic contactor to start and stop
the inverter, do not exceed one stop per hour.
Recommended MCCB and magnetic contactor
• 200V 3-Phase
VS mini J7 model
Capacity
Rated Output Current
MCCB type NF30
(MITSUBISHI)
Magnetic contactor type HI
(YASKAWA CONTROL)
• 200V single-Phase
VS mini J7 model
Capacity
Rated Output Current
MCCB type NF30, NF50
(MITSUBISHI)
Magnetic contactor type HI
(YASKAWA CONTROL)
• 400V 3-Phase
VS mini J7 model
Capacity
Rated Output Current
MCCB type NF30, NF50
(MITSUBISHI)
Magnetic contactor type HI
(YASKAWA CONTROL)
J7 * *
J7 * *
J7 * *
20P1
20P2
20P4
(kVA)
0.3
0.6
1.1
(A)
0.8
1.6
3
5A
5A
5A
HI-7E
HI-7E
HI-7E
J7 * *
J7 * *
B0P1
B0P2
(kVA)
0.3
0.6
(A)
0.8
1.6
5A
5A
HI-7E
HI-7E
J7 * *
J7 * *
40P1
40P2
(kVA)
0.9
1.4
(A)
1.2
1.8
5A
5A
HI-7E
HI-7E
J7 * *
J7 * *
J7 * *
20P7
21P5
22P2
1.9
3.0
4.2
5
8
11
10A
20A
20A
HI-7E
HI-10-2E
HI-10-2E
J7 * *
J7 * *
B0P4
B0P7
1.1
1.9
3
5
10A
20A
HI-7E
HI-10-2E
J7**
J7 * *
J7 * *
40P4
41P5
42P2
2.6
3.7
4.2
3.4
4.8
5.5
5A
10A
10A
HI-7E
HI-10-2E
HI-10-2E
J7 * *
23P7
6.7
17.5
30A
HI-20E
J7 * *
B1P5
3.0
8
20A
HI-15E
J7 * *
43P7
7.0
9.2
20A
HI-10-2E
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents