Ignition Switch Testing

Hourmeter Replacement

Hourmeter Removal
Hourmeter Installation
Hourmeter Testing
Electrical: Service and Repairs
g353109
Using a digital multimeter set to the OHM or Continuity setting, verify the
following:
Position
OFF
RUN
START
1. Connect the battery by installing the positive cable first, then the negative
cable to the battery.
2. Disconnect the battery by removing the negative cable first, then the positive
cable from the battery.
3. Remove the control panel. Refer to
4. Compress the 2 tabs on the side of the switch and remove the hourmeter.
1. Insert the hourmeter into the control panel.
2. Install the control panel. Refer to
3. Connect the battery by installing the positive cable first, then the negative
cable to the battery.
With the ignition switch in the RUN position and the PTO switch closed (ON),
verify battery voltage and ground to the hourmeter.
Figure 142
Control Panel Removal (page
Control Panel Installation (page
Page 8–18
Circuit Continuity
None
B+R+I+A
B+R+I+S
8–9).
8–12).