Endress+Hauser PROline prosonic flow 90 Operating Instructions Manual page 54

Ultrasonic flow measuring system
Hide thumbs Also See for PROline prosonic flow 90:
Table of Contents

Advertisement

5 Operation
54
Byte
Bit
Error no.
0
not assigned
1
not assigned
2
not assigned
3
not assigned
4
4
not assigned
5
not assigned
6
not assigned
7
not assigned
0
not assigned
1
not assigned
2
not assigned
3
not assigned
5
4
not assigned
5
not assigned
6
not assigned
7
339
0
340
1
341
2
342
3
343
6
4
344
5
345
6
346
7
347
0
348
1
349
2
350
3
351
7
4
352
5
353
6
354
7
355
0
356
1
357
2
358
3
359
8
4
360
5
361
6
362
7
not assigned
o
Short error description (
Current buffer:
The temporarily buffered flow portions (measuring mode for pul-
sating flow) could not be cleared or output within 60 seconds.
Frequency buffer:
The temporarily buffered flow portions (measuring mode for pul-
sating flow) could not be cleared or output within 60 seconds.
Pulse buffer:
The temporarily buffered flow portions (measuring mode for pul-
sating flow) could not be cleared or output within 60 seconds.
Current output: flow is out of range.
Frequency output: flow is out of range.
Pulse output: the pulse output frequency is out of range.
PROline Prosonic Flow 90