3. APPLIANCE DATA AND EFFICIENCY

3.1 General information.

Gas
Inlet Pressure
Input - Max. (Gross)
Input - Min. (Gross)
Input - Max. (Net)
Input - Min. (Net)
Inlet Test Pressure (Cold)
Gas Connection
Burner Injector
Pilot & Atmosphere Sensing
Device
Ignition
Aeration
* When converted using Kit 0595221.
The appliance information label is located on a plate at the base of the fire. This can
be seen by removing the firefront.

3.2 Efficiency.

The efficiency of this appliance has been measured as specified in BS 7977 - 1 and
the result is as below :
Model
956
956 when converted to LPG
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica
Certification services (0087). The efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
©
GDC Group Ltd 2014
INSTALLER GUIDE
Natural (G20)
20mbar
6.0kW (20,500Btu/h)
2.3kW (7,850Btu/h)
5.4kW (18427Btu/h)
2.07kW (7063Btu/h)
20.0 ± 1.0mbar
(8.0 ± 0.4in w.g.)
8mm pipe
Cat 82 - 069
Copreci Ref. O.D.S
21500/166
Piezo Electric. Integral with
Gas Tap
Factory set
Efficiency % (Gross)
Page 9
Propane (G31) *
6.1kW (20,800Btu/h)
3.8kW (12,965Btu/h)
5.61kW (19147Btu/h)
3.50kW (11928Btu/h)
37.0 ± 1.0 mbar
(14.85 ± 0.4in w.g.)
Copreci Ref. O.D.S
21500/166 Fitted with RBM
180 - 02 injector
Piezo Electric. Integral with
Non-adjustable
51
52
37mbar
8mm pipe
Size 128
Gas Tap
Efficiency % (Net)
56
56