Fireplace Clearances - Valor Brava 347 Installation And Owner's Manual

Radiant / convector gas fire
Table of Contents

Advertisement

4.7 Fireplace clearances.

4.7.1 The minimum allowable distance from the outside of the appliance fascia to a
corner wall having combustible material or any other combustible surface which
projects beyond the front of the appliance is 50mm at either side (See figure 2).
Although no side clearance is necessary to non-combustible surfaces we recommend
a 100mm clearance for service access to fascia side fixing.
Model
Dimension 'A' (mm)
Brava
609
Figure 2. Dimensions and clearances
4.7.2 Allow a minimum clearance of 90mm from the top surface of the appliance
fascia to the underside of any shelf whether it is made from combustible or non-
combustible materials. This clearance is necessary to allow the fascia to be lifted off
for servicing and also allows the owner sufficient access to operate the control knob.
For a shelf made from wood or other combustible materials deeper than 150mm,
the minimum clearance must be as below.
• For a shelf up to 150mm deep: Minimum clearance = 90mm.
• For a shelf deeper than 150mm: 90mm + 12.5mm for every 25mm depth over
150mm (See Figure 3).
©
GDC Group Ltd. OCT 2016
INSTALLER GUIDE
Dimension 'B' (mm)
713
Page 12
Dimension 'C' (mm)
177

Advertisement

Table of Contents
loading

Table of Contents