List Of Accessories; Appliance Data, Efficiency And Nox - Valor BRAVA 348 Installer And Owner Manual

Radiant / convector
Table of Contents

Advertisement

Description
Spigot extension
Control knob extension kit
4. APPLIANCE DATA, EFFICIENCY AND NO x
3.1 Appliance data.
Inlet Pressure
Input - Max. (Gross)
Input - Min. (Gross)
Burner Test Pressure (Cold)
Gas Connection
Burner Injector - Upper (Centre Radiants)
Burner Injector - Lower (Outer Radiants)
Pilot & Atmosphere Sensing Device
The appliance information label is on the inner face of the back panel at the lower left
hand side. It is visible when the fascia is removed.
3.2 Efficiency.
The efficiency of this appliance has been measured as specified in BS 7977 - 1 and
the result is as below:
Model
348 Brava Fireslide
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by GL Industrial
services (0087). The efficiency value may be used in the UK Government's Standard
Assessment Procedure (SAP) for energy rating of dwellings.
©
GDC Group Ltd. 2011
INSTALLER GUIDE

3. LIST OF ACCESSORIES

Gas
Ignition
Aeration
Part number
0595191
5138166
5.4 kW (18,424 Btu/h)
2.7 kW (9,212 Btu/h)
17.8 + 0.75mbar (7.14 + 0.3in w.g.)
COPRECI 21100/235-HK
Electronic spark generator
Efficiency % (Gross)
Page 8
Natural (G20)
20mbar
8mm pipe
Cat 28 - 170
Cat 28 - 170
Non-adjustable
74.0