Valor Brava 347 Installation And Owner's Manual page 20

Radiant / convector gas fire
Table of Contents

Advertisement

5.6.1 Hearth mounting
(See figure 8).
The closure plate must be fitted and
sealed to the hearth and fireplace
opening using a suitable heat
resistant material. If necessary cut
the closure plate but make sure that it
overlaps the fireplace opening
sufficiently to allow satisfactory
sealing. Make sure that the square air
relief opening is fully within the
fireplace opening.
5.6.2 Wall mounting
(See figure 9).
The closure plate must be fitted and
sealed to the hearth and fireplace
opening using a suitable heat
resistant material. If necessary cut
the closure plate but make sure
that it overlaps the fireplace
opening sufficiently to allow
satisfactory sealing. Make sure
that the square air relief
opening is fully within the
fireplace opening.
The bottom of the appliance
must be at least 50mm above
any carpet or other floor
covering. To achieve this, the
bottom of the flue spigot
opening must be at least the
minimum dimension shown in
figure 9.
©
GDC Group Ltd. OCT 2016
INSTALLER GUIDE
Figure 8. Closure plate when hearth mounting.
Figure 9. Closure plate when wall mounting.
Page 20

Advertisement

Table of Contents
loading

Table of Contents