6.6 Flue restrictor adjustment.

(See figure 14).
The appliance has an integral adjustable flue
draught restrictor. This is supplied set in the
fully open (unrestricted) position and in most
cases no adjustment should be necessary. It
can be reset to a fully restricted position if the
flue draught is excessive. The restrictor must
remain in its fully open position if the flue has
an equivalent height of 4m or less (as
calculated in accordance with BS5440: Part 1
Appendix B). Generally we recommend the
restrictor is NOT fitted where a precast flue is
used, however, certain flues may work
sufficiently to warrant its use. There may
however, be circumstances where fitting the
restrictor causes the fire to fail the spillage test.
In such cases the restrictor will have to be re-
opened. After opening conduct the spillage
check again.
To close the restrictor:
1. Loosen the screw situated behind the cut-out in the black upper heat shield. Do not
fully remove the screw (See figure 14).
2. Push the restrictor firmly down as far as it will go. The top of the slot in the
restrictor bracket should touch the screw.
3. Fully tighten the screw.
If closing the restrictor causes the fire to fail the spillage test it will have to be
reopened.
To open the restrictor:
1. Loosen the screw situated behind the cut-out in the black upper heat shield. Do not
fully remove the screw.
2. Push the restrictor firmly up as far as it will go. The bottom of the slot in the
restrictor bracket should touch the screw.
3. Fully tighten the screw.
©
GDC Group Ltd. OCT 2016
INSTALLER GUIDE
Page 23
Figure 14. Flue restrictor
adjustment