Valor BOLERO BR626 Installer's Manual

Brass/chrome/black, inset live fuel effect gas fire
Hide thumbs Also See for BOLERO BR626:

Advertisement

I
N
S
T
A
L
L
E
R
G
U
I
D
E
For
V A L O R B O L E R O
( M O D E L B R 6 2 6 )
9 5 0 0 4 3 6 - B r a s s
9 5 0 0 4 3 7 – C h r o m e
9 5 0 0 4 3 8 - B l a c k
I n s e t L i v e F u e l
E f f e c t G a s
F i r e
GB
IE
G . C .
N o .
3 2 - 0 3 2 - 1 0
Please keep in a safe place for future reference
600B350/04

Advertisement

Table of Contents
loading

Summary of Contents for Valor BOLERO BR626

  • Page 1 V A L O R B O L E R O ( M O D E L B R 6 2 6 ) 9 5 0 0 4 3 6 - B r a s s 9 5 0 0 4 3 7 – C h r o m e 9 5 0 0 4 3 8 - B l a c k I n s e t L i v e F u e l E f f e c t G a s...
  • Page 2 Valor conversion kit 591159. This Installer Guide gives sufficient details to enable the appliance to be installed and maintained. If further information is required, our Valor AdviceLine will be pleased to help. Please telephone 0345 626341 (Local call rates apply)
  • Page 3: Installation Notes

    I NST AL LAT I ON NOT ES In your own interest and for safety, in the United Kingdom, it is the law that all gas appliances are installed by competent persons in accordance with the current edition of the Gas Safety (Installation & Use) Regulations and Amendments.
  • Page 4: Technical Specification

    The A.S.D will shut the appliance down if an unacceptable amount of harmful products of combustion accumulate. Under no circumstances should the A.S.D be altered or bypassed in any way. Only a genuine Valor supplied replacement part should be fitted. The individual A.S.D components are not replaceable.
  • Page 5 LOCATION This appliance is not suitable for installation in a room or internal space containing a bath or shower, or where steam is regularly present or in a private garage. This appliance is suitable for the following:- A masonry chimney with a minimum diameter of 175mm (7”) free from any obstruction, and with any damper or restrictor plate in the chimney removed or secured, and having a minimum effective flue height of 3m (10ft).
  • Page 6: Installation And Commissioning Instructions

    Fire Surround: This appliance may be installed with a surround with a minimum approved temperature rating of 150 degrees. The fire surround must be sealed to the wall. Hearth Requirements: The appliance must be mounted on a non-combustible hearth in accordance with Figure 3.
  • Page 7 Cable Retention: Cables and eyebolts are supplied for the retention of the appliance. Ensure that the internal fireplace components are sufficiently sound to take the eyebolts and wall plugs. Drill two holes in the rear wall of the fireplace for the eyebolt plugs using a No.10 masonry drill. The nominal position of the holes should be as shown in figure 5.
  • Page 8: Preliminary Burner Checks

    Push the free length of the cables inside the convection box so that they are available to allow easy removal and refitting of the appliance during subsequent service calls. If the sealing foam does not fully compress, then the adjusters and nipples may require to be slackened and the cable pulled up tighter before re-tightening the adjuster.
  • Page 9: Check Reference Pressure

    If the above checks are satisfactory, continue with the installation. If not, check the control and ignition circuitry and components as described in the servicing section of this manual. CHECK REFERENCE PRESSURE The appliance is pre-set to give the correct heat input at the inlet pressure shown in the Technical Specification section of this manual.
  • Page 10 Place the rear base coal matrix in the burner compartment directly behind the front coal. It should rest on the ledge at the back of the burner compartment. (See Figure 9). Figure 9 Rear Base Matrix positioning Install the 14 loose coals as follows. Begin the coal build by placing a single coal in the centre of the front coal, ensuring that it bridges across to the matrix as shown in figure 10.
  • Page 11 Place a single coal upon the two peaks of the coal matrix directly behind the centre line of the first row of coals see Figure 12. Figure 12 First Coal Of Second Row of Coals Place four coals, two each side of the centre coal directly behind the front row of coals (Figures 13).
  • Page 12: Recheck Control Settings

    This monitoring system must not be adjusted, bypassed or put out of operation. This monitoring system, or any of its parts, must only be exchanged using Valor Authorised parts.
  • Page 13: Final Review

    FITTING THE CAST FASCIA. Ensure the fire has been turned off and has been allowed to cool before fitting the fascia. The Bolero is supplied with a high grade cast fascia and fire front. Remove the fascia from the packaging taking care not to use a sharp implement that may scratch the surface of the fascia.
  • Page 14: To Replace Burner Plaques

    SERVICING Always turn off the gas supply before commencing any servicing. (The inlet elbow for this appliance incorporates an isolating valve). This product uses fuel effect pieces, burner compartment walls and gaskets containing Refractory Ceramic Fibres (RCF), which are man-made vitreous silicate fibres. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract.
  • Page 15: To Remove The Piezo Generator

    TO REMOVE THE GAS TAP/F.S.D • Remove the burner unit. • Disconnect the electrode lead from tab underneath the electrode. • Undo the thermocouple nut at the gas tap • Disconnect the inlet pipe at the tap end • Disconnect the pilot pipe at the tap end. •...
  • Page 16: Short List Of Spares

    SHORT LIST OF SPARES DESCRIPTION PART NO. Injector Bray cat 31 size 440 - For Natural Gas Appliances 569539 Injector Bray cat 18 size 180 - For Propane Gas Appliances 577949 Gas tap & spark generator 569429 Spark generator 521069 Control knob 545979 Pilot Unit –...
  • Page 17 Type of fire. Model/Name. Serial Number. The fault, problem or request. General advice about gas and your gas fire: VALOR ADVICELINE 0345 626341. To report faults or arrange for your fire to be serviced: VALOR SERVICE 0121 386 6203. To order spares or for sales information: VALOR SALES 0121 386 6260.
  • Page 18 BS EN ISO 9001 quality system accepted by the British Standards Institute. The Highest Standards Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety, quality and performance. Careful Installation Valor is a Corgi registered company.

Table of Contents