Unpacking & Pre-Installation Preparation; Carton Contents; Fireplace Flue Pull Check; Appliance Preparation - Valor regency 328 Installation & Servicing Instructions Manual

Radiant / convector
Table of Contents

Advertisement

Valor Folium Format U/down 12/4
INSTALLATION & SERVICING INSTRUCTIONS
3. UNPACKING & PRE-
INSTALLATION PREPERATION
3.1

CARTON CONTENTS

The carton contains:
1 Fire assembly
3 Radiants (In pack in radiant box)
1 Closure plate
1 Floor plate
1 Flue spigot
1 Spigot restrictor
4 Screws for spigot
1 Set of installation & users instructions
Carefully remove the contents. Check that
all the listed parts are present and in
satisfactory condition.
3.2.
FIREPLACE FLUE PULL
After preparing the fireplace, apply a
lighted match, paper or smoke match to
the chimney opening. Observe the smoke.
If there is a definite flow into the opening
continue with the installation. If there is
not a definite flow, preheat the chimney for
a few minutes and recheck If there is still
no definite flow, the chimney may need
attention. Do not fit the appliance. Seek
expert advice.
3.3.

APPLIANCE PREPARATION

Stand the fire on its base.
Remove the dress guard by pressing down
3.3.1.
the two hooks at the top. Tilt the guard
forward and lift out.
Remove the two (one each side) side trim
3.3.2.
retaining screws which are located in the
bottom edge of the hood just above the
side trims. Remove the side trims by
pulling forward and up to clear the
retaining slots.
Lift up the bottom panel and pull forward to
3.3.3.
clear.
Remove the radiant pack.
3.3.4.
Remove any protective film from all the
3.3.5.
bright trims.
Check ignition spark
3.3.6.
Before attempting to install, it is worth
5/22/00
9:33 AM
Page 7
checking that the piezo electric spark
ignition system operates satisfactorily.
To initiate the spark, depress the control
knob and while keeping it depressed, turn to
the 1/IGN position. A spark should track from
the electrode pin to the thermocouple tip. If
there is no spark or incorrect tracking, check
the spark gap between the electrode wire and
thermocouple tip (see figure 3) . If the spark
gap is correct, check the ignition wiring.
figure 3
Fit the flue spigot to the back of the fire
3. 3.7.
using four screws provided. The fire is
supplied with a spigot restrictor which is
intended for use where the flue draught is
excessive. The restrictor must not be fitted
to a flue with an effective height less than
4m or where a precast flue is used. Where
the restrictor is required, fit it, at this stage,
between the flue spigot and the back of the
fire. There may, however, be certain
exceptional circumstances where fitting
the restrictor causes the fire to fail the
spillage test (see section 5.3.4). In such
cases the restrictor will have to be
removed.
If the fire is fitted to a recessed fireplace,
3.3.8.
an extension flue spigot up to a maximum
total length of 125mm may be used. The
extension must be a tight fit over the flue
spigot and be secured by two self tapping
screws. Note the minimum clearance
required as shown in figure 2 .
Page 7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Favourite 322Firelite 328

Table of Contents