Output Settings; Judgment Output Selection - Panasonic HL-G1 A-C5 Series User Manual

Compact laser displacement sensor
Hide thumbs Also See for HL-G1 A-C5 Series:
Table of Contents

Advertisement

Chapter 3 Function

3-3-5 Output Settings

 Judgment Output Selection
This function makes it possible to select the operation of the output block.
An alarm will not be output if "3-state" is selected.
The final decision process is done in digital measurements. When an alarm is
turned ON, the value will be set to +999.9999 with which judgment processing will
be performed, provided that a fixed value has been set with "digital output at
alarm".
Judgment Output
Selection
3
Logic
Independent
2-state
3-state
*
Output operation
OUT1
OUT2
OUT3
Judgment
Judgment
Alarm
1
2
Judgment
Judgment
Alarm
1
2
Judgment
Judgment
Alarm
1
2
Judgment
Judgment
Judgment
1
2
3
indicates the default value.
Display
Threshold a
Threshold b
ON
Output status
OUT1
(OPEN)
OFF
ON
OUT2
(OPEN)
OFF
ON
(OPEN)
OUT1
OFF
ON
OUT2
(OPEN)
Output status
OFF
ON
OUT1
(OPEN)
Output status
OFF
ON
OUT2
(OPEN)
OFF
ON
(OPEN)
OUT1
(HI)
OFF
ON
(OPEN)
OUT2
OFF
(GO)
ON
OUT3
(OPEN)
Output status
(LO)
OFF
3-22
Displacement (+)
Output status
Output status
Output status
Output status
Output status
Output status
Output status

Advertisement

Table of Contents
loading

Table of Contents