3-3-2 Memory Change

The memory to save setting contents can be changed with M0 through M3.
Setting
M0
M1
M2
M3
*
indicates the default value.
• Select the first number to be changed when the system goes into setting mode.
• A memory change will not switch the current memory until the memory change is
executed after the system restarts.
• Data unstability may result when the memory change is executed.
• If setting changes are made with a serial communications command, save the
changes so that the changes will be reflected when the system is turned ON again.
● Setting Procedure
1
Display the "Memory Change" screen
while the system is in setting mode.
2
Press the [ENTER] key. The memory
will be displayed.
3
Press the [UP]/[DOWN] key to make
memory changes. (Example: Changing
the memory to "M3".)
4
Press the [ENTER] key to determine the
memory.
● Memory Saving Settings
Each function that has been set can be saved in four ways in the memory
area in the sensor head.
Measurement and judgment conditions can be saved individually according to the
type of measurement object. Therefore, memory number changes will be possible
without entering the set values for a wide variety of functions.
Memory changes are made with external commands and settings in the control
panel.
Function
Memory M0
Memory M1
Memory M2
Memory M3
3-11
Chapter 3 Function
Panel display