3-3-3 Sensing Setting

 Sampling Cycle
This function is used to make measurement cycle settings.
When measuring an object with poor received light intensity, such as black
rubber, extend the sampling cycle to get sufficient light to perform stable
measurement.
Cycle
200 μs
500 μs
1 ms
2 ms
*1 The measurement range may become narrow depending on measurement
object type.
*2
● Setting Procedure
1
Display the "Sensing Setting" screen
while the system is in setting mode.
2
Press the [ENTER] key. The
"Sampling Cycle" screen will be
displayed.
3
Press the [ENTER] key. The present
sampling cycle will be displayed.
4
Press the [UP]/[DOWN] key to make
sampling cycle changes. (Example:
Changing the sampling cycle to 1 ms.)
5
Press the [ENTER] key to determine
the sampling cycle.
Frequency
5 kHz
2 kHz
1 kHz
500 Hz
indicates the default value.