Settings Related To Bcd Output Unit (Optional); Overview Of Specifications Of Bcd Output Unit; Overview Of Specifications Of Bcd Output Unit - Panasonic GP-X Series User Manual

Digital displacement sensor
Hide thumbs Also See for GP-X Series:
Table of Contents

Advertisement

5.2 Settings Related to BCD Output Unit (Optional)

5.2.1 Overview of Specifications of BCD Output Unit
High-speed digital output can be obtained through connection of a BCD
output unit (GP-XBCD) (optional) and a cable with connector on one end for
BCD output unit (GP-XBCC3) (optional). Digital output is superior in regards
to resistance to external noise when compared with analog output, and sta-
ble and high resolution can be obtained without filter circuits.
For CE compliance, mount an EMC compliant ferrite clamp to the BCD output
cable with the connector on the single side. (For details, refer to page 11.)
[Recommended product: ZCAT2035-0930A made by TDK Co., Ltd.]
When the BCD output is used, analog voltage output cannot be used.
Make sure that the detection sampling period changes. If an analog volt-
Notice
age output is connected to external devices, disconnects.
Terminal
Name
No.
1
A0
1x
2
B0
2x
3
C0
4x
4
D0
8x
5
A1
1x
6
B1
2x
7
C1
4x
8
D1
8x
9
A2
1x
10
B2
2x
11
C2
4x
12
D2
8x
13
A3
1x
14
B3
2x
15
C3
4x
16
D3
8x
17
A4
1x
18
B4
2x
19
C4
4x
20
D4
8x
21
POLE
22
VALID
23
HOLD
24
GND
25
1: The cable marked with three black dots on a white background is not connected.
100
Cable
ID mark
Color of insulator
Red, 1 pc.
Orange
Black, 1 pc.
Units digit of
setting
Red, 1 pc.
Gray
Black, 1 pc.
Red, 1 pc.
White
Black, 1 pc.
Tens
Red, 1 pc.
setting
Yellow
Black, 1 pc.
Red, 1 pc.
Pink
Black, 1 pc.
Hundreds digit
Red, 2 pcs.
of setting
Orange
Black, 2 pcs.
Red, 1 pc.
Gray
Black, 2 pcs.
Thousands digit
of setting
Red, 2 pcs.
White
Black, 2 pcs.
Red, 2 pcs.
Yellow
Black, 2 pcs.
Ten thousands
digit of setting
Red, 2 pcs.
Pink
Black, 2 pcs.
Orange
Red, 3 pcs.
Polarity signal output
Orange
Black, 3 pcs.
VALID output
Hold input
Gray
Red, 3 pcs.
Gray
Black, 3 pcs.
Ground
White
Red, 3 pcs.
White
Black, 3 pcs.
Connected to 0V inside.
Shield
Detailed description
digit
of
BCD output of measured value
High(OFF):
, LOW(ON):
Low (ON) upon effective data
output.
Input from an external device for holding
data output. The data output is retained
while the input remains low (ON).
Not used.

Advertisement