3-3-7 Alarm Settings

 Analog Output at Alarm
This function is used to set the analog output status at alarm operation.
Analog output in the alarm state (where measurement is disabled owing to lack of
light) can be kept on hold or set to a fixed value selectively.
Setting
Hold
Fixed Value
*
indicates the default value.
Supplemental remarks
• A fixed current output of 21.6 [mA] or voltage output of +11.000 [V] applies.
• The fixed value is applied to the side set with "Analog Output Selection."
• Check the input range of your input device such as AD board before setting.
• The above settings will apply when there is data unstability.
● Setting Procedure
1
Display the "Alarm Setting" screen while
in setting mode.
2
Press the [ENTER] key. The "Analog
output at alarm" will be displayed.
3
Press the [ENTER] key. The Hold/Fix
will be displayed.
4
Press the [UP]/[DOWN] key to set the
system to Hold/Fix. (Example: Changing
the selection to the fixed value.)
5
Press the [ENTER] key to determine the set
value.
Function
Holds the analog output
immediately before the alarm.
Fixed-value output
3-31