Chapter 4 Communications Control
● Error code
Error
code
01
02
03
04
11
21
22
31
4
32
33
• If an abnormal response is received, check if there are any errors such as
transmission data errors. Correct such errors, if any. If an error occurs
regardless of the absence of mistakes, it may be a temporal phenomenon
caused by noise or other external reasons or the external host device may
have a system error. Turn the sensor head or system turned OFF and ON.
Code type
Command error
The command is undefined.
Address error
The start address is larger than the end address or the
address is larger than 999999 when the RDD or WDD
command is executed.
The address length has not reached the prescribed
length when the RDD or WDD command is executed.
Data error
The data length does not correspond to the command.
The data length has not reached the prescribed length.
BCC error
BCC check was not conformable.
Communication
A parity error occurred during data reception.
error
A framing error occurred during data reception.
An overrun error occurred during data reception.
Control flow error The system is in setting mode.
Execution error
Calibration or analog scaling is not executable.
Buffering
An attempt was made to make a buffering setting
condition error 1
change without stopping buffering.
Buffering
An attempt was made to start buffering with an
condition error 2
inadequate buffering setting.
Buffering
Data was read after buffering operation started.
condition error 3
Data was read while the system was not in the
accumulation completed status.
Data in excess of the final data point was specified and
read.