Checking Of The Float Chamber - Rotax MML-912 Maintenance Manual

Table of Contents

Advertisement

10.4) Checking of the float chamber

See
General note
To check of the float chamber the following steps are necessary:
Instruction
Step
1
2
3
4
5
Step
6
7
Effectivity: 912 Series
Edition 2 / Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Fig.
21.
Risk od Burns!
WARNING
WARNUNG
Hot engine parts!
Always allow engine to cool down to ambient tempera-
ture before start of any work.
Remove drip tray (1).
Open spring clip (2).
Remove float chamber (3) with gasket (4) and both float.
Remove both float (5) from the float chamber.
Inspect the float chamber for contamination and corrosion.
If any contamination on float chamber the find out what
NOTICE
WARNUNG
the cause is and take corresponding action to rectify
the problem. Inspect and clean the complete fuel sys-
tem including carburetor.
Assembly at the float chamber should be carried out analogously the disas-
sembly.
Adjust with the idle speed adjustment.
See chap. 12-20-00 section: 10.5).
Procedure
Procedure
12-20-00
page 41
October 01/2009