Step
1
2
3
4
5
Option 4
Graphic
Fig. 19
Effectivity: 912 Series
Edition 2 / Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Install the vacuum gauge.
Clamp the tube (2) with hose clamping pliers (1). Observe the position! The
compensation tube (3) must not removed.
Unscrew the screw (4).
Install the hose nipple M6 (5) with the sealing ring (6).
After synchronization tightened the screw M6x6 (4) with LOCTITE 221.
3
2
Part
1
Clamping pliers
2
Tube
3
Compensation tube
4
Screw
5
Hose nipple
6
Sealing ring
Option 4
Procedure
1
5
4
6
Function
08661
12-20-00
page 37