Engine test run is necessary:
Engine test run
Step
1
2
3
4
5
Oil level check/Replenish
Graphic
Fig. 3
Effectivity: 912 Series
Edition 2 / Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Operate the engine until the temperatures have stabilized for a period of 5 min
(engine oil temperature between 50 to 70 °C (122 - 160 °F).
Switch the engine OFF.
Allow the engine to cool down.
Check for leaks.
Check the oil level and top up with oil as required.
1
2
Part
1
Oil tank cover
2
Oil dipstick
Procedure
Function
12-10-00
08524
page 10