11.7) Purging the oil system

General note
Purging the oil system is necessary:
Procedure
- before each first start up
- after reinstallation (e.g. after overhaul)
- after maintenance work during which the lubrication system was
opened and voided.
Effectivity: 912 Series
Edition 2 / Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Purging of the oil system is extremely important for op-
NOTICE
WARNUNG
eration and service life of the engine and therefore the
procedure must be followed meticulously. It must be
carried out in accordance with SI-912-018,"Purging
the lubrication system", latest issue.