7.
Blow the air filter out with dry compressed air (max. 5 bar
(73 psi)) from inside to outside by moving the gun up and
B-GEN-0042
down inside the element, until it is free of dust.
8.
Examine the air filter with a torch for cracks and holes.
9.
Replace the air filter if it is damaged.
10.
Insert the air filter (1) carefully into the filter housing and
1
fasten it with the knurled nut (2).
2
11.
3
Close the cap (3).