Semi-Annually; Battery Service - Fayat Group DYNAPAC DRP25D Original Operating Instructions

Reversible plate
Table of Contents

Advertisement

8.8 Semi-annually

8.8.1 Battery service

Fig. 69
2
Fig. 70
5
4
Fig. 71
B-SYM-1077
Protective equipment:
1.
2.
1
2
3
B-692-0038
3.
1
4.
2
5.
6.
3
7.
B-692-0039
8.
Maintenance – Semi-annually
Maintenance free batteries also need care. Mainte-
nance free only means that the fluid level does not
need to be checked.
Every battery has a self-discharge, which may, if
not checked occasionally, even cause damage to
the battery as a result of exhaustive discharge.
Exhausted batteries (batteries with formation of
sulphate on the plates) are not covered under war-
ranty!
n
Working clothes
n
Safety shoes
n
Protective gloves
n
Safety goggles
Park the machine safely
in secured condition' on page 59.
Remove the battery box cover.
Remove the battery (2) and the vibration damping mats (1, 3,
4, 5).
Check the condition of the vibration insulation mats, replace if
necessary.
Clean the outside of the battery.
Clean battery poles and pole clamps and grease them with
pole grease (Vaseline).
Install the battery and vibration damping mats and check the
battery fastening.
On serviceable batteries check the acid level, if necessary
top up to the filling mark with distilled water.
DRP25D
Ä Chapter 6.4 'Parking the machine
79