Cust Early Write; Custom Run Cal; Custom Tag Pos - Printronix SL4M Reference Manual

Rfid labeling
Hide thumbs Also See for SL4M:
Table of Contents

Advertisement

Chapter 2
RFID CONTROL Menu (SL5000r)

Cust Early Write

NOTE: To enable this menu item, set both Custom Tag and
IMPORTANT
Change this menu item with caution. If the write is performed
too early, the wrong tag will be written.
This menu item selects how early the RFID encoder will write the
next tag before it completes the printing on the current label.
Certain tag types are designed to allow early tag writing for
maximum print speed. The default is 0.40 inches.
NOTE: The units display in inches or millimeters, depending on the

Custom Run Cal

NOTE: To enable this menu item, set Custom Tag to Enable.
This menu item causes the printer to run calibration for the current
RFID tags installed in the printer. After the calibration is complete,
the custom settings are changed to work with the tags installed.
These settings do not take effect until Custom Tag is set to Enable.

Custom Tag Pos

NOTE: To enable this menu item, set Custom Tag to Enable.
This menu item determines how far the RFID tag position of the
currently installed custom tags differs from the RFID tag position of
the standard Printronix tag. Printronix printers print at maximum
speed with RFID labels that have RFID tags in the standard
position. The default is 0.0 inches.
NOTE: The units display in inches or millimeters, depending on the
34
Early Write to Enable.
Units setting (in the MEDIA CONTROL menu).