Admin User Menu Items (SL4M)
Admin User Menu Items (SL4M)
To see these menu items, set Admin User to Enable in the
PRINTER SETUP menu. (Refer to the User's Manual .)
IMPORTANT
Admin User menu items should only be used by authorized
personnel.
Error Handling
This menu item selects the error handling mode for RFID failures.
The default is Overstrike.
In Overstrike mode, each failed label prints with the Overstrike
pattern and the form retries on a new label until the Label Retry
count is exhausted. Whether or not an error message will display or
the failed label will reprint depends upon the Max Retry Error
setting.
In None mode, no specific action is taken when a tag fails to be
programmed.
In Stop mode, when a tag fails to be programmed, the printer will
halt and display the error message "RFID Error: Check Media." The
label is discarded and reprinting of the label (if desired) must be
initiated from the host. When the error is cleared, the label with the
failed tag moves forward until the next label is in position to be
printed.
Max Retry Error
This menu item enables or disables Max Retry Error. If it is set to
Disable, errors are not declared and the print content for the current
label is discarded. The default is Enable.
Clear Tag Stat
This menu item clears the Tag Write Cnt, Failed Tag Cnt, Tag Void
Cnt, and Tag Read Cnt menu items.