Chapter 2
RFID Menu (SL4M)
Scan Start Pos
This menu item determines where on the label the RFID calibration
will begin. By default, the calibration procedure will start at the
beginning of the label (0.0 inches). To make the calibration work
faster, change this value to force the calibration to begin after the
beginning of the label.
NOTE: The units display in inches or millimeters, depending on the
Scan Length
The menu item determines how much of the label will be scanned
during the RFID calibration procedure. The default is 3.0 inches.
NOTE: The units display in inches or millimeters, depending on the
Cal Min Power
The menu item determines the minimum power level that the
calibration procedure will use when attempting to find the ideal
power level. To make the calibration work faster, increase this
value to exclude the lower power levels. The default is 1.
Cal Max Power
The menu item determines the maximum power level that the
calibration procedure will use when attempting to find the ideal
power level. To make the calibration work faster, decrease this
value to exclude the higher power levels. The default is 20.
EPC Mgr Report
This menu item enables EPC and label information to be sent out
the network port. This information can be used by an RFID tag data
and labels manager program. The default is Disable.
48
Units setting (in the MEDIA CONTROL menu).
Units setting (in the MEDIA CONTROL menu).