Table 4. Printed Overstrike Error Messages
Error Message
Tag R/W Err x
Check media
Tag Comm Err x
Check cable
NOTE: The x in the error messages represents a number code that
Custom Setting
This menu item contains submenus that allow the RFID encoder to
work with tag types that are not listed in the Tag Type menu item.
NOTE: Printronix cannot guarantee the performance of tag types
Custom Setting Submenus
Custom Tag
This menu item enables or disables the Custom Setting submenus.
The default is Disable.
When Custom Tag is set to Disable, the settings in the Custom
Setting submenus are ignored by the RFID encoder.
When it is set to Enable, the RFID encoder uses the settings in the
Custom Setting submenus, which must be set to match the
characteristics of the custom tag.
When it is set to Duplicate, the settings of the selected Tag Type
menu item are copied into the Custom Setting submenus, but are
ignored by the RFID encoder.
Explanation
The printer software attempted to write to or read from the
RFID tag, but the RFID encoder indicated that the tag could
not be written to or read from.
The printer software temporarily lost communication with the
RFID encoder, or communication between the printer
software and the RFID encoder was not synchronized and
had to be forced.
identifies the area in the printer software or RFID encoder
where the failure occurred.
not certified by Printronix.
Admin User Menu Items (SL4M)
45
Need help?
Do you have a question about the SL4M and is the answer not in the manual?
Questions and answers