Table 5. Control Panel Error Messages
Error Message
RFID MAX RETRY
Check System
RFID TAG ERR:
Read-Only Tag
RFID TAG FAILED
Check Media
RFID UNLOCK CMD:
Not Supported!
RFID ACS FIELD:
Not Supported!
RFID KIL FIELD:
Not Supported!
RFID PC FIELD:
Not Supported!
Explanation
Error Handling = Overstrike in
the RFID (or RFID
CONTROL) menu, and the
Label Retry count has been
exhausted.
A write was attempted on a
read-only tag.
Error Handling = Stop in the
RFID (or RFID CONTROL)
menu, and the RFID encoder
could not read the RFID tag.
An unlock command was
executed on a tag which does
not support locking.
The ACS field was accessed
on a tag which does not
support the ACS field.
The KIL field was accessed
on a tag which does not
support the KIL field.
The PC field was accessed
on a tag or RFID encoder
which does not support the
PC field.
Solution
Press PAUSE to clear the
message.
See "Troubleshooting" on
page 90.
Press PAUSE to clear the
message.
Change media to writable
tags or remove the write
command from the
application.
Press PAUSE to clear the
message.
See "Troubleshooting" on
page 90.
Press PAUSE to clear the
message.
Remove the unlock
command from the
application.
Press PAUSE to clear the
message.
Remove references to the
ACS field from the
application.
Press PAUSE to clear the
message.
Remove references to the
KIL field from the
application.
Press PAUSE to clear the
message.
Remove references to the
PC field from the application.