Mcu And Gateway Dialing Problems And Solutions - Polycom ReadiManagerSE200 Operator's Manual

Polycom readimanagerse200 network: operator guide
Hide thumbs Also See for ReadiManagerSE200:
Table of Contents

Advertisement

Polycom ReadiManager SE200 Operator's Guide

MCU and Gateway Dialing Problems and Solutions

Problem
Call fails when using an
MCU service.
Dialing an MCU service
results in a network error.
Simplified dialing does not
work.
When you dial 9, you
receive a network error.
7–8
Description
The call using the MCU service is
rejected because of one of the
following:
The MCU is not registered.
The MCU is offline.
The MCU prefix is not
registered as an E.164 alias.
The MCU resource issue was
sent through resource
allocation indication or resource
allocation.
The dialing rule is not enabled.
The priority of the dialing rule
may be too high.
Services are not enabled.
The call using the simplified dialing
service is rejected because of one
of the following:
The simplified dialing prefix
service in the system
configuration is disabled.
No gateway services are
available.
There is insufficient BRI/PRI
bandwidth.
The call uses a higher bit rate
than the device policy group
allows.
Solutions
Review the Gatekeeper Diagnostic
screen for the ARJ reason to
determine why the call failed.
Verify that the MCU is registered.
Select it on the Monitoring Devices
screen and view the device's status.
Verify that the MCU device in the
Monitoring Devices list is online. If the
device is offline, reboot it.
Verify that the MCU service is
available. Go to the Administrator
View > Dial Plan Setup > Services
screen. Verify that the MCU service
prefix is enabled and listed.
Check the Gatekeeper Diagnostics log
for error messages.
Verify that the simplified dialing service
prefix is enabled. Go to Administrator
View > Dial Plan Setup > Services.
Verify that the gateway is registered.
Verify that the gateway prefix is defined
and enabled. Go to Administrator
View > Dial Plan Setup > Services.
Verify that the LocalDS dialing rule is
enabled and the action setting is route.
Verify that the device policy bit rate limit
has not been exceeded.

Advertisement