Example
T01PEQIBT,2,40
T01PEQIBT,1,?
8.80. PEQIE -- Set Enabled Parameter for Specified
Parametric EQ Input Stage
This command sets or queries the enabled parameter (0 = filter is disabled, 1 = filter is enabled) for
the parametric equalizer (EQ) filters on input channel T. Each channel has five bands of parametric EQ
that can be independently controlled.
This command has the same format and restrictions as the
parameter, the enabled status, is specified instead of all the parameters. See the
more information. To set the enabled parameter for an output parametric EQ filter, use the
command. To set all the parameters for an output parametric EQ filter, use the
This command is saved to non-volatile memory only as part of a preset. The state of this command will
be restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example
Description
Enable parametric EQ on input T,
T01PEQIET,2,1
band 2.
Query enabled status of
T01PEQIET,1,?
parametric EQ on input T, band 1.
8.81. PEQIF -- Set Frequency Parameter for Specified
Parametric EQ Input Stage
This command sets or queries the frequency parameter (in Hz) for the parametric equalizer (EQ) filters
on input channel T. Each channel has five bands of parametric EQ that can be independently controlled.
The minimum and maximum values for the frequency parameter are 20 and 20000, respectively.
Description
Set bandwidth of parametric EQ
on input T, band 2 to 40
1/100th octaves.
Query current bandwidth setting
of parametric EQ on input T,
band 1.
Status Message
T01PEQIBT,2,40
T01PEQIBT,1,b, where b is the current setting
of the bandwidth parameter for the parametric
EQ on input T, band 1. If the bandwidth
parameter of this filter is set to the same value
given in the example above, then the status
message will be T01PEQIBT,1,40.
command except that only one
PEQIA
Status Message
T01PEQIET,2,1
T01PEQIET,1,e, where e is the current
setting of the enabled parameter for the
parametric EQ on input T, band 1. If the
enabled parameter of this filter is set to the
same value given in the example above, then
the status message will be T01PEQIET,1,1.
command for
PEQIA
PEQOE
command.